12
WOLF L SERIES BUILT-IN OVENS
IMPORTANT
NOTE
You must follow
all National
Electrical Code
regulations. In
addition, be aware
of local codes and
ordinances when
installing your
service.
Verify that power is disconnected from
electrical box before proceeding.
M
aximum connected load:
5
.1 kW
for 30" (762) and 36" (914) single ovens;
8.9 kW for the double oven.
Required power supply:
240V/208V/
30A/60Hz for 30" (762) and 36" (914) single
ovens; 240V/208V/50A/60Hz for the double
oven.
Minimum supply wire size:
L1, L2 and
ground – 10 AWG; neutral – 12 AWG
Total electric rating:
5.1 kW at 240 V,
3.8 kW at 208 V for 30" (762) and 36" (914)
single ovens with a minimum 30 amp
service; 8.9 kW at 240 V, 6.7 kW at 208 V for
the double oven with a minimum 50 amp
service.
Total amps:
21 amps for 30" (762) and 36"
(914) single ovens; 37 amps for the double
oven.
The built-in oven is provided with a conduit
consisting of two insulated hot lead conduc-
tors (copper), one insulated neutral conductor
(copper), and one uninsulated ground conduc-
tor (copper).
For UL installations:
attach the conductors
to the residence wiring in accordance with
National Electrical Codes and all state,
municipal and local codes.
For CSA installations:
attach the conductors
to the electrical box provided. Then connect
the residence wiring to the electrical box in
accordance with all national, provincial and
local codes.
With the oven positioned directly in front of
the cabinet opening, feed the appliance cable
through the opening in the cabinet platform
(where applicable). Then, depending upon
local codes, utilize one of the following
techniques to connect the appliance to the
electrical power supply.
ELECTRICAL REQUIREMENTS
The complete appliance must be properly
grounded at all times when electrical
power is applied.
Grounding through the neutral conductor
is prohibited for new branch-circuit
installations (1996 NEC); mobile homes;
and recreational vehicles, or in an area
w
here local codes prohibit grounding
through the neutral conductor.
If aluminum house supply wiring is
utilized, splice the appliance copper wir
e
to the aluminum house wiring using
special connectors design and agency
certified for joining copper and
aluminum. Follow the connector manu-
facturer's recommended procedure
carefully. NOTE: Improper connection can
result in a fire hazard.
Comentarios a estos manuales