Undercounter Use & Care 13
subzero.com
Cleaning
CONDENSER CLEANING
Clean the condenser area every three to six months. The
cleaning schedule will depend on the amount of dust and
lint that accumulates in this area.
The condenser is located behind the kickplate. Remove
the kickplate to expose the condenser area. Refer to the
illustration below. Use a soft bristle brush and vacuum
hose to remove dust and lint from the condenser area. To
avoid bending the condenser fins, be sure to vacuum in
the direction of the fins (up and down).
Interior Lighting
M
odel UC-24BG has rope-style lighting mounted to the
top interior of the cabinet that cascades down the sides of
the unit. This lighting is visible through the glass door.
All undercounter models have a recessed light bulb in the
ceiling of the unit. To change the bulb, remove the 25-watt
bulb by unscrewing it from the socket. Install a new
replacement bulb. Refer to the illustration below.
Condenser location.
Light bulb location.
Shut off power to the unit before replacing the light
bulb. Wear protective gloves when handling bulbs.
Failure to clean the condenser could result in tempera-
ture loss or mechanical failure or damage.
Before cleaning the condenser, shut off power to the
unit at the control panel. When you clean the
condenser, wear gloves to avoid injury from the sharp
condenser fins.